Type |
N/A Bimetal Thermometer |
Series |
N/A 100 |
Case and Bezel Material |
N/A 304 Stainless Steel |
Temperature Range [Min] |
N/A 25 ºF |
Temperature Range [Max] |
N/A 125 ºF |
Full Scale Accuracy (±) |
N/A 1.0 % |
Accuracy Grade |
N/A A |
Accuracy Standard |
N/A American Society of Mechanical Engineers (ASME) B40.3 |
Connection Size |
N/A 1/4 in |
Lens |
N/A Instrument Glass |
Dial Size |
N/A 2 in |
Case Type |
N/A Back Connection |
Temperature Scale |
N/A Single |
Connection Type |
N/A National Pipe Thread (NPT) |
Pointer |
N/A Aluminum, Black Finished |
Dial |
N/A Anodized Aluminum with large black numbers and graduations |
Wetted Parts Material |
N/A 304 Stainless Steel |
Optional Wetted Parts Material |
N/A 316 Stainless Steel |
Optional Case and Bezel Material |
N/A 316 Stainless Steel |
Hermetic Seal |
N/A Per American Society of Mechanical Engineers (ASME) B40.3 dustproof and leakproof |
Bimetal Coil |
N/A Silicone coated helix coil on ranges below 500 ºF for vibration dampening, maximum heat transfer and response time |
Warranty |
N/A 1 y |
Limits Over Temperature at 100 Percentage |
N/A Up to 250 ºF |
Limits Over Temperature at 50 Percentage |
N/A 250 to 500 ºF |
Limits Over Temperature at Continuous Use Up to 800 ºF |
N/A 550 to 1,000 ºF |
Limits Over Temperature at Intermittent Use Over 800 ºF |
N/A 550 to 1,000 ºF |
Stem Lengths |
N/A 4 in |
Stem Diameter |
N/A 0.250 in6.35 mm |
Stock |
N/A Yes |
Application |
N/A
|
Options and Accessories |
N/A
|
100 Series Bimetal Thermometer Silicone Filled (SL) |
N/A
|
Mounting Flanges - Bimetal Thermometers |
N/A Various sizes and types of mounting flanges are available |
Special Dials - Bimetal Thermometers |
N/A Special ranges and dials with company names, company logos, part numbers, telephone numbers, or almost any custom layout is available |
Certified Calibration |
N/A
|
Stem Types |
N/A
|
Thermowells |
N/A Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument. |
Prop 65 Warnings |
N/A
![]() |
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |