Part Number |
Description |
Pressure [Max] |
Full Scale Best Fit Straight Line (BFSL) Accuracy (±) |
Output Signal |
Cable Length |
List Price |
---|---|---|---|---|---|---|
613-10-1-1-15 | N/A 0 to 10 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Cage Protected Submersible Transducer with 15 ft Polyurethane (PUR) Cable | N/A 0 to 10 psi | N/A 0.125 %0.25 % | N/A 4 mA to 20 mA, 2-wire | N/A 15 ft | Quote |
613-10-1-1-30 | N/A 0 to 10 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Cage Protected Submersible Transducer with 30 ft Polyurethane (PUR) Cable | N/A 0 to 10 psi | N/A 0.125 %0.25 % | N/A 4 mA to 20 mA, 2-wire | N/A 30 ft | Quote |
613-10-1-1-40-LR | N/A 0 to 10 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Cage Protected Submersible Transducer with 40 ft Polyurethane (PUR) Cable and Lifting Ring | N/A 0 to 10 psi | N/A 0.125 %0.25 % | N/A 4 mA to 20 mA, 2-wire | N/A 40 ft | Quote |
613-10-1-1-50 | N/A 0 to 10 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Cage Protected Submersible Transducer with 50 ft Polyurethane (PUR) Cable | N/A 0 to 10 psi | N/A 0.125 %0.25 % | N/A 4 mA to 20 mA, 2-wire | N/A 50 ft | Quote |
613-10-1-1-50-FE | N/A 0 to 10 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Cage Protected Submersible Transducer with 50 ft Polyurethane (PUR) Cable and Filter Element | N/A 0 to 10 psi | N/A 0.125 %0.25 % | N/A 4 mA to 20 mA, 2-wire | N/A 50 ft | Quote |
613-15-1-1-20 | N/A 0 to 15 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Cage Protected Submersible Transducer with 20 ft Polyurethane (PUR) Cable | N/A 0 to 15 psi | N/A 0.125 %0.25 % | N/A 4 mA to 20 mA, 2-wire | N/A 20 ft | Quote |
613-15-1-1-40-LR | N/A 0 to 15 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Cage Protected Submersible Transducer with 40 ft Polyurethane (PUR) Cable and Lifting Ring | N/A 0 to 15 psi | N/A 0.125 %0.25 % | N/A 4 mA to 20 mA, 2-wire | N/A 40 ft | Quote |
613-15-1-1-50 | N/A 0 to 15 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Cage Protected Submersible Transducer with 50 ft Polyurethane (PUR) Cable | N/A 0 to 15 psi | N/A 0.125 %0.25 % | N/A 4 mA to 20 mA, 2-wire | N/A 50 ft | Quote |
613-15-1-1-50-LR | N/A 0 to 15 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Cage Protected Submersible Transducer with 50 ft Polyurethane (PUR) Cable and Lifting Ring | N/A 0 to 15 psi | N/A 0.125 %0.25 % | N/A 4 mA to 20 mA, 2-wire | N/A 50 ft | Quote |
613-15-1-1-75 | N/A 0 to 15 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Cage Protected Submersible Transducer with 75 ft Polyurethane (PUR) Cable | N/A 0 to 15 psi | N/A 0.125 %0.25 % | N/A 4 mA to 20 mA, 2-wire | N/A 75 ft | Quote |
613-30-1-1-100 | N/A 0 to 30 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Cage Protected Submersible Transducer with 100 ft Polyurethane (PUR) Cable | N/A 0 to 30 psi | N/A 0.125 %0.25 % | N/A 4 mA to 20 mA, 2-wire | N/A 100 ft | Quote |
613-50-1-1-200-LR | N/A 0 to 50 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Cage Protected Submersible Transducer with 200 ft Polyurethane (PUR) Cable and Lifting Ring | N/A 0 to 50 psi | N/A 0.125 %0.25 % | N/A 4 mA to 20 mA, 2-wire | N/A 200 ft | Quote |
613-5-1-1-12-CBC-LR | N/A 0 to 5 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Cage Protected Submersible Transducer with 12 ft Polyurethane (PUR) Cable, Cable Clamp, and Lifting Ring | N/A 0 to 5 psi | N/A 0.125 %0.25 % | N/A 4 mA to 20 mA, 2-wire | N/A 12 ft | Quote |
613-5-1-1-25 | N/A 0 to 5 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Cage Protected Submersible Transducer with 25 ft Polyurethane (PUR) Cable | N/A 0 to 5 psi | N/A 0.125 %0.25 % | N/A 4 mA to 20 mA, 2-wire | N/A 25 ft | Quote |
613-5-1-1-50 | N/A 0 to 5 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Cage Protected Submersible Transducer with 50 ft Polyurethane (PUR) Cable | N/A 0 to 5 psi | N/A 0.125 %0.25 % | N/A 4 mA to 20 mA, 2-wire | N/A 50 ft | Quote |
613-5-1-1-50-CBC-DC-LR | N/A 0 to 5 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Cage Protected Submersible Transducer with 50 ft Polyurethane (PUR) Cable, Cable Clamp, Desiccant Cartridge, and Lifting Ring | N/A 0 to 5 psi | N/A 0.125 %0.25 % | N/A 4 mA to 20 mA, 2-wire | N/A 50 ft | Quote |
613-5-1-1-50-LR | N/A 0 to 5 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Cage Protected Submersible Transducer with 50 ft Polyurethane (PUR) Cable and Lifting Ring | N/A 0 to 5 psi | N/A 0.125 %0.25 % | N/A 4 mA to 20 mA, 2-wire | N/A 50 ft | Quote |