Print Back
  • Proven 100 Ω platinum resistance sensor provides reliability, stability & unbeatable performance
  • Economical price
  • Wide variety of temperature ranges and connections
Unit of Measure

Specifications

Type

N/A Transmitter

Series

N/A 800

Electromagnetic Rating

N/A European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:1997/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection

Connection Type

N/A Male National Pipe Thread (MNPT)

Wetted Materials

N/A 316 Stainless Steel

Temperature Ranges [Min]

N/A 0 ºF

Temperature Ranges [Max]

N/A 140 ºF

Housing Material

N/A 316 Stainless Steel

Connection Size

N/A 1/2 in

Output Signal

N/A 0 to 10 Vdc, 3-Wire

Electrical Connection

N/A DIN EN 175301-803 Form A

Power Supply

N/A 10 to 30 Vdc (4 to 20 mA, 2-Wire)
10 to 30 Vdc (0 to 5 Vdc, 3-Wire)
10 to 30 Vdc (1 to 5 Vdc, 3-Wire)
14 to 30 Vdc (0 to 10 Vdc, 3-Wire)
Accuracy1 N/A Class B + (±0.5 % Best Fit Straight Line (BFSL))

Storage Temperature [Max]

N/A 85 ºC185 ºF

Storage Temperature [Min]

N/A -40 ºC-40 ºF

Standard Temperature Ranges

N/A -40 to 120 ºF50 to 400 ºF

Sensor Protection

N/A Burnout Protected from 3.3 to 23 mA

Measuring Element

N/A Class B per Norm European Standards (EN) 60751 (International Electrotechnical Commission (IEC 751))

Output

N/A ±[0.30 + 0.005 ltl] ºC
±0.5% Full Scale

Load Limitations

N/A ≤(VPower - 10)/0.020 Amp for 4 to 20 mA output
≤5000 Ω for 1 to 5 Vdc output
≤10, 000 Ω for 0 to 10 Vdc output
≤4500 Ω for 0.5 to 4.5 Vdc output

Pressure Rating

N/A 725 psi

Ambient Temperature Range

N/A -40 to 185 ºF-40 to 85 ºC

Environmental Protection

N/A Ingress Protection (IP65) According to Norm European Standards (EN) 60529/(International Electrotechnical Commission (IEC 529))

Electrical Protection

N/A Reverse polarity, over-voltage and short circuit protection

Approximate Weight

N/A 4 oz

Warranty

N/A 3 y

Stem Diameters

N/A 6 mm

Stem Lengths

N/A 9 in

Related Items

N/A 50-090-304-SS, 1/2" National Pipe Thread (NPT) Stepped Shank, 9" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell (Quote)
75-090-304-SS, 3/4" National Pipe Thread (NPT) Stepped Shank, 9" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell ($115.68)
75-090-316-SS, 3/4" National Pipe Thread (NPT) Stepped Shank, 9" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell ($129.33)

Prop 65 Warnings

Prop 65 Warnings

N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Application

Application

N/A
  • Water systems
  • Storage tanks
  • Industrial machinery and machine tools
  • HVAC systems
  • Refrigeration systems

Limitations Which Apply Are

Limitations Which Apply Are

N/A These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.

In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.

Additional Information

Additional Information

N/A
  • Quick response time
  • Also available with our 1800 Series attachable loop indicator (see options & accessories below)
  • CE compliant to suppress RFI, EMI, and ESD

Options and Accessories

1800 Series Attachable Loop-Powered Digital Indicators

N/A NOSHOK 1800 Series Attachable Loop-Powered Digital Indicators can be fitted to certain NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the DIN EN 175301-803 Form A Electrical Connection.

Thermowells

N/A Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument.

Note

Note

N/A Thermowells are recommended for pressure, corrosive fluids and high velocity applications.
  • 1 Max. error on complete span. Error at calibration point ≤0.1 ºC