Catalog

  • Current and voltage outputs available
  • 316 Stainless Steel wetted parts
  • Can be cleaned-in-place (CIP) or steamed-in-place (SIP)
  • 3A Certified
  • CE compliant to suppress RFI, EMI and ESD
Unit of Measure
Items
11 Series Sanitary Transmitter

1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), -30 inHg to 100 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A Connection with ISO 4400 1/2 in. National Pipe Thread (NPT) Conduit

11 Series Sanitary Transmitter

1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 5 psig, 4 to 20 mA Output Sanitary Transducer with M12 x 1 (4-Pin)

11 Series Sanitary Transmitter

1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 5 psig, 4 to 20 mA Output Sanitary Transducer with 36" Integral Cable

11 Series Sanitary Transmitter

1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 15 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A

11 Series Sanitary Transmitter

1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 60 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A (36" Cable Attached)
Description N/A
  • Current and voltage outputs available
  • 316 Stainless Steel wetted parts
  • Can be cleaned-in-place (CIP) or steamed-in-place (SIP)
  • 3A Certified
  • CE compliant to suppress RFI, EMI and ESD
Type N/A Pressure Transmitter
Clamp Size N/A 1-1/2 in
Weight N/A 1.1 lb
Storage Temperature [Min] N/A -40 ºC212 ºF
Storage Temperature [Max] N/A -40 ºC100 ºF
Housing Material N/A 316 Stainless Steel
Full Scale Best Fit Straight Line (BFSL) Accuracy (±) N/A 0.125 %0.25 %
Output Signal N/A 4 mA to 20 mA, 2-Wire, 0 Vdc to 5 Vdc 3-Wire, 1 Vdc to 5 Vdc 3-Wire, 1 Vdc to 6 Vdc 3-Wire, 0 Vdc to 10 Vdc, 3-Wire, 1 Vdc to 11 Vdc 3-Wire
Electrical Connection N/A DIN EN 175301-803 Form A Connection with International Organization for Standardization (ISO) 4400 1/2 in. National Pipe Thread (NPT) Conduit N/A M12 x 1 (4-Pin) N/A Integral 36 in. Cable N/A DIN EN 175301-803 Form A (DIN European Standard (EN) 175301-803 Form A) N/A 36 in. Cable attached to DIN EN 175301-803 Form A
Environmental Rating N/A Ingress Protection (IP65)
Series N/A 11
Connection Material N/A 316 Stainless Steel
Seal Fill Fluid N/A FFL77 White Oil
Transducer N/A Series 615 transducer
Pressure Range N/A -30 inHg to 100 psig N/A 0 to 5 psig N/A 0 to 5 psig N/A 0 to 15 psig N/A 0 to 60 psig
Stability N/A ±0.2% full scale for 1 year, non-accumulating
Adjustment N/A ±10% full scale for zero and span
Response Time N/A ≤10 ms
Service Life N/A > 100,000,000 Load Cycles
Compensated Temperature Range N/A 30 to 175 ºF0 to 80 ºC
Note for Compensated Temperature Range N/A Effect ±0.01%/ºF for zero and span
Media Temperature Range N/A -40 to 300 ºF-40 to 150 ºC
Ambient Temperature Range N/A -40 to 176 ºF-40 to 80 ºC
Power Requirement N/A 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-Wire, 0 Vdc to 5 Vdc, 3-Wire, 1 Vdc to 5 Vdc, 3-Wire, 1 Vdc to 6 Vdc, 3-Wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-Wire, Vdc to 11 Vdc, 3-Wire)
Current for 4 to 20 Milliampere (mA) N/A 0.020 A
Resistance for 1 to 5 Direct Current (DC) Voltage Output N/A ≤ 5,000 Ω
Resistance for 0 to 10 Direct Current (DC) Voltage Output N/A ≤ 10,000 Ω
Resistance for 0.5 to 4.5 Direct Current (DC) Voltage Output N/A ≤ 4,500 Ω
Measuring Element N/A 316 Stainless Steel
Electrical Protection N/A Reverse polarity, over-voltage and short circuit protection
Electromagnetic Rating N/A European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection
Shock According to International Electrotechnical Commission (IEC) 60068-2-27 N/A 1,000 g
Vibration According to International Electrotechnical Commission (IEC) 60068-2-6 N/A 150 g
Warranty N/A 3 y
Limitations Which Apply Are N/A These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.

In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Options and Accessories N/A
  • NBR Gaskets
    • 3/4" (BG-06)
    • 1-1/2" (BG-12)
    • 2" (BG-16)
  • PTFE Gaskets
    • 3/4" (TG-06)
    • 1-1/2" (TG-12)
    • 2" (TG-16)
  • ASME-BPE Sanitary Clamp
    • 3/4" (CR-06)
    • 1-1/2" (CR-12)
    • 2" (CR-16)
  • Attachable Loop Digital Indicator (1800-0) (For use with DIN EN 175301-803 Form A Electrical Connector (8) only)
Application N/A
  • Food & beverage processing
  • Pasteurization systems
  • Pharmaceutical
  • Medical
Caution N/A NOSHOK pressure transmitters or transducers are not to be used in heat sterilization systems as stated in 3A Standard 74-03 paragraph D10.1.2.

Diaphragm seal must be installed facing downward or in a vertical position for drainability. Do not install diaphragm seal facing in an upward position.
Digital Indicators N/A NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters.
Sanitary Clamps and Gaskets N/A
  • Clamp-style fittings are constructed of T304 Stainless Steel; T316 Stainless Steel on request
  • Double hinge design for easy installation and removal
  • Available in sizes from 3/4" to 4"
  • Standard pressure rating of 500 psi at 70 ºF (21 ºC); up to 3,000 psi rating on request
  • Clamp gaskets are available in NBR, EPDM, PTFE and FKM
  • All clamps and gaskets meet FDA and 3A sanitary standards
ASME-BPE Sanitary Clamp
1-1/2" (CR 12)
2" (CR 16)
2-1/2" (CR 20)
3" (CR 24)

NBR Gasket
1-1/2" (BG 12)
2" (BG 16)
2-1/2" (BG 20)
3" (BG 24)

PTFE Gasket
1-1/2" (TG 12)
2" (TG 16)
2-1/2" (TG 20)
3" (TG 24)
Prop 65 Warnings N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov