Skip To Content

Catalog

  • Current output
  • 316 Stainless Steel and 17-4PH Steel wetted parts
  • Canadian Standards Association approved
  • CE compliant to suppress RFI, EMI and ESD
Unit of Measure
Items
627 Series Intrinsically Safe Submersible Pressure Transmitters

0 to 10 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Submersible Pressure Transmitter with Nose Cone and 42 ft Polyurethane (PUR) Cable

627 Series Intrinsically Safe Submersible Pressure Transmitters

0 to 15 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Submersible Pressure Transmitter with Nose Cone and 30 ft Fluorinated Ethylene Propylene (FEP) Cable

627 Series Intrinsically Safe Submersible Pressure Transmitters

0 to 15 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Submersible Pressure Transmitter with Nose Cone and 40 ft Fluorinated Ethylene Propylene (FEP) Cable

627 Series Intrinsically Safe Submersible Pressure Transmitters

0 to 25 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Submersible Pressure Transmitter with Nose Cone and 20 ft Polyurethane (PUR) Cable

627 Series Intrinsically Safe Submersible Pressure Transmitters

0 to 30 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Submersible Pressure Transmitter with Nose Cone and 15 ft Polyurethane (PUR) Cable
Description N/A
  • Current output
  • 316 Stainless Steel and 17-4PH Steel wetted parts
  • Canadian Standards Association approved
  • CE compliant to suppress RFI, EMI and ESD
Type N/A Liquid Level Transmitter
Series N/A 627
Approximate Weight N/A 7 oz
Storage Temperature [Min] N/A -10 ºC14 ºF
Storage Temperature [Max] N/A 60 ºC140 ºF
Housing Material N/A 316 Stainless Steel
Burst Pressure N/A
Output Signal N/A 4 mA to 20 mA, 2-wire; 1 Vdc to 5 Vdc low power, 3-wire; 0.5 Vdc to 4.5 Vdc low power, 3-wire
Response Time N/A
Full Scale Best Fit Straight Line (BFSL) Accuracy (±) N/A 0.125 %0.25 %
Note for Accuracy N/A For ranges ≥ 150 inH2O (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors).
Environmental Rating N/A Ingress Protection (IP68)
Electrical Connection N/A 42 feet Standard Polyurethane (PUR) Cable N/A 30 feet Fluorinated Ethylene Propylene (FEP) Cable N/A 40 feet Fluorinated Ethylene Propylene (FEP) Cable N/A 20 feet Standard Polyurethane (PUR) Cable N/A 15 feet Standard Polyurethane (PUR) Cable
Connection Material N/A Stainless Steel Nose Cone
Pressure Range N/A 0 to 10 psig23.1 ftH2O N/A 0 to 15 psig34.6 ftH2O N/A 0 to 15 psig34.6 ftH2O N/A 0 to 25 psig57.7 ftH2O N/A 0 to 30 psig69.2 ftH2O
Stability N/A ≤ ±0.2% full scale for 1 year, non-accumulating
Response Time N/A ≤1 ms
Service Life N/A < 100,000,000 load cycles
Compensated Temperature Range N/A 32 to 122 ºF0 to 50 ºC
Note for Compensated Temperature Range N/A Zero effect is ±0.011% full scale/ºF within compensated range
Span effect is ±0.011% full scale/ºF within compensated range
Media Temperature Range N/A 14 to 140 ºF-10 to 60 ºC
Ambient Temperature Range N/A 14 to 140 ºF-10 to 60 ºC
Power Requirement N/A 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire)
Proof Pressure N/A 2 Times Range
Burst Pressure N/A 3 Times Range
Diaphragm and Cap Material N/A 316 Stainless Steel
Measuring Element N/A 17-4PH stainless steel for 0 psig to 350 psig
Cable Material N/A Polyurethane, Fluorinated Ethylene Propylene
Electrical Protection N/A Reverse polarity, over-voltage and short circuit protected
Cable Length N/A 42 ft N/A 30 ft N/A 40 ft N/A 20 ft N/A 15 ft
Electromagnetic Rating N/A European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection
Application N/A
  • Irrigation
  • Tank monitoring
  • Water & wastewater
  • Well head measurement
Additional Information N/A NOSHOK 627 Series transmitters are Canadian Standards Association approved for use in hazardous location applications as follows:
  • Intrinsically Safe, entity approval for Class I, II and III, Division 1, Groups A, B, C, D, E, F, and G; and Class I, Zone 0 Aex ia IIC
  • Dust ignition-proof for Class II and III, Division 1, Groups E, F, and G
  • Non-incendive for Class I, Division 2, Groups A, B, C, and D
  • FMRC 3,600, 3,610, 3,611, 3,810 (including supplement #1)
  • ISA-S12.0.01, IEC 60529 (including amendment #1)
  • CE compliant with pressure equipment directive 97/23EC
Prop 65 Warnings N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Options and Accessories N/A
  • Cable Clamp (CBC)
  • Cable Junction Box (NEMA 4X) (JB)
  • Desiccant Cartridge (DC)
  • Filter Element (FE)
Load Limitations N/A ≤ (VPower-10)/0.020 Amp-(0.043 Ω x length of cable in feet)
Note N/A Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information.

Back to Top