Skip To Content

Catalog

  • Proven 100 Ω platinum resistance sensor provides reliability, stability & unbeatable performance
  • Economical price
  • Wide variety of temperature ranges and connections
Unit of Measure
Items
800 Series Platinum Resistance Temperature Transmitters

800 Series 0/100 ºF Temperature Range, 4 to 20 mA Output, 1/2" National Pipe Thread (NPT) Process Connection, 12" Stem, and 6 mm Diameter Temperature Transmitter with DIN EN 175301-803 Form A Electrical Connection

800 Series Platinum Resistance Temperature Transmitters

800 Series 0/140 ºF Temperature Range, 4 to 20 mA Output, 1/4" National Pipe Thread (NPT) Process Connection, 2.5" Stem, and 6 mm Diameter Temperature Transmitter with DIN EN 175301-803 Form A Electrical Connection

800 Series Platinum Resistance Temperature Transmitters

800 Series 0/140 ºF Temperature Range, 4 to 20 mA Output, 1/2" National Pipe Thread (NPT) Process Connection, 6" Stem, and 6 mm Diameter Temperature Transmitter with DIN EN 175301-803 Form A with 36" Cable Electrical Connection

800 Series Platinum Resistance Temperature Transmitters

800 Series 0/140 ºF Temperature Range, 4 to 20 mA Output, 1/2" National Pipe Thread (NPT) Process Connection, 2.5" Stem, and 6 mm Diameter Temperature Transmitter with DIN EN 175301-803 Form A Electrical Connection

800 Series Platinum Resistance Temperature Transmitters

800 Series 0/140 ºF Temperature Range, 4 to 20 mA Output, 1/2" National Pipe Thread (NPT) Process Connection, 4" Stem, and 6 mm Diameter Temperature Transmitter with DIN EN 175301-803 Form A Electrical Connection
Description N/A
  • Proven 100 Ω platinum resistance sensor provides reliability, stability & unbeatable performance
  • Economical price
  • Wide variety of temperature ranges and connections
Type N/A Transmitter
Series N/A 800
Electromagnetic Rating N/A European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:1997/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection
Connection Type N/A Male National Pipe Thread (MNPT)
Wetted Materials N/A 316 Stainless Steel
Temperature Ranges [Min] N/A 0 ºF
Temperature Ranges [Max] N/A 100 ºF N/A 140 ºF N/A 140 ºF N/A 140 ºF N/A 140 ºF
Housing Material N/A 316 Stainless Steel
Connection Size N/A 1/2 in N/A 1/4 in N/A 1/2 in N/A 1/2 in N/A 1/2 in
Output Signal N/A 4 to 20 mA, 2-Wire
Electrical Connection N/A DIN EN 175301-803 Form A N/A DIN EN 175301-803 Form A N/A DIN EN 175301-803 Form A with 36" Cable N/A DIN EN 175301-803 Form A N/A DIN EN 175301-803 Form A
Power Supply N/A 10 to 30 Vdc (4 to 20 mA, 2-Wire)
10 to 30 Vdc (0 to 5 Vdc, 3-Wire)
10 to 30 Vdc (1 to 5 Vdc, 3-Wire)
14 to 30 Vdc (0 to 10 Vdc, 3-Wire)
Accuracy1 N/A Class B + (±0.5 % Best Fit Straight Line (BFSL))
Storage Temperature [Max] N/A 85 ºC185 ºF
Storage Temperature [Min] N/A -40 ºC-40 ºF
Standard Temperature Ranges N/A -40 to 120 ºF50 to 400 ºF
Sensor Protection N/A Burnout Protected from 3.3 to 23 mA
Measuring Element N/A Class B per Norm European Standards (EN) 60751 (International Electrotechnical Commission (IEC 751))
Output N/A ±[0.30 + 0.005 ltl] ºC
±0.5% Full Scale
Load Limitations N/A ≤(VPower - 10)/0.020 Amp for 4 to 20 mA output
≤5000 Ω for 1 to 5 Vdc output
≤10, 000 Ω for 0 to 10 Vdc output
≤4500 Ω for 0.5 to 4.5 Vdc output
Pressure Rating N/A 725 psi
Ambient Temperature Range N/A -40 to 185 ºF-40 to 85 ºC
Environmental Protection N/A Ingress Protection (IP65) According to Norm European Standards (EN) 60529/(International Electrotechnical Commission (IEC 529))
Electrical Protection N/A Reverse polarity, over-voltage and short circuit protection
Approximate Weight N/A 4 oz
Long Term Drift N/A
Excitation Current Resistance Temperature Device (RTD) N/A
Sensor Lead Resistance Temperature Device (RTD) [Max] N/A
Span/Zero Adjustment N/A
Maximum Loop Resistance N/A
Open Circuit Detection Overscale Limit N/A
Open Circuit Detection Underscale Limit N/A
Warm Up N/A
Options N/A
Warranty N/A 3 y
920 Series Resistance Temperature Device (RTD) Transmitter Options and Accessories N/A
Degree of Protection N/A
Stem Diameters N/A 6 mm
Stem Lengths N/A 12 in N/A 2.5 in N/A 6 in N/A 2.5 in N/A 4 in
Length N/A
Width N/A
Height N/A
Prop 65 Warnings N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Application N/A
  • Water systems
  • Storage tanks
  • Industrial machinery and machine tools
  • HVAC systems
  • Refrigeration systems
Limitations Which Apply Are N/A These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.

In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.
Additional Information N/A
  • Quick response time
  • Also available with our 1800 Series attachable loop indicator (see options & accessories below)
  • CE compliant to suppress RFI, EMI, and ESD
1800 Series Attachable Loop-Powered Digital Indicators N/A NOSHOK 1800 Series Attachable Loop-Powered Digital Indicators can be fitted to certain NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the DIN EN 175301-803 Form A Electrical Connection.
Thermowells N/A Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument.
Related Items N/A , 1/2" National Pipe Thread (NPT) Stepped Shank, 12" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell
, 1/2" National Pipe Thread (NPT) Stepped Shank, 12" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell
, 3/4" National Pipe Thread (NPT) Stepped Shank, 12" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell
N/A N/A , 1/2" National Pipe Thread (NPT) Stepped Shank, 6" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell
, 1/2" National Pipe Thread (NPT) Stepped Shank, 6" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell
, 3/4" National Pipe Thread (NPT) Stepped Shank, 6" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell
, 3/4" National Pipe Thread (NPT) Stepped Shank, 6" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell
N/A , 1/2" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell
, 1/2" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell
, 3/4" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell
, 3/4" National Pipe Thread (NPT) Straight Shank, 2-1/2" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell
N/A , 1/2" National Pipe Thread (NPT) Straight Shank, 4" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell
, 3/4" National Pipe Thread (NPT) Straight Shank, 4" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell
, 3/4" National Pipe Thread (NPT) Straight Shank, 4" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell
Note N/A Thermowells are recommended for pressure, corrosive fluids and high velocity applications.
  • 1 Max. error on complete span. Error at calibration point ≤0.1 ºC

Back to Top