Print Back
The heart of the LNG Vaporizer Assembly is the well-known HPR-2 Series heated pressure control valve. This unit has been used in many successful applications requiring heating of a process stream sample prior to analysis to prevent freeze up or for vaporization. The HPR-2 is a modularized unit consisting of a heated section and pressure control section. A field demonstration has now shown this vaporizer assembly to be serviceable in the vaporization of LNG product for analytical purposes andmore
Unit of Measure

Specifications

Brands

GO Regulator, Inc.

Electrically Heated

Construction for Electrically Heated

316L Stainless Steel

Outlet Pressures for Electrically Heated

0 to 10 psig0 to 25 psig0 to 50 psig0 to 100 psig0 to 250 psig0 to 500 psig

Inlet Pressure for Electrically Heated

Up to 3600 psig at 380 ºF (193 ºC)

Heating Capacity Ranges

40 W50 W100 W150 W

Certifications

Atmospheres Explosibles (ATEX) Directive 2014/34/EU Canadian Standards Association (CSA) Certification # LR-82566-5 Certification # TRL03ATEX11001X

Typical Applications

Typical Applications

  • LNG loading and off-loading points
  • Petrochemical refineries
  • Chemical production facilities
  • Natural gas pipelines

Features and Benefits

Features and Benefits

  • Optional HASTELLOY® C-276 and MONEL®
  • Electropolished body with better than 25 Refinish in diaphragm cavity for an optimal sealing surface
  • Bubble-tight shutoff
  • Modular pressure control and heat exchanger assemblies for easy maintenance
  • Unique spiral wrapped heat exchange element provides up to 100 square inches of heat transfer area
  • Available in 120VAC or 230VAC and steam-heated
  • Optional TCO heating cartridge for T3 operation
  • INCONEL® diaphragm standard

Note

Note

  1. Contact the factory for any additional requirements.
  2. Units that will be used for flammable liquid or gas with fire point at 200ºC or below require the TCO Thermistor. It is also recommended to use the 1-PC body option. In addition, Tefzel® and PCTFE seats in these units are recommended to use the captured vent cap option which provides for venting to a safe location.