Type |
N/A Probe |
Series |
N/A 900 |
Connection Type |
N/A Male National Pipe Thread (MNPT) |
Temperature Ranges [Min] |
N/A -50 ºF |
Temperature Ranges [Max] |
N/A 400 ºF |
Connection Size |
N/A 1/2 in |
Accuracy1 | N/A ±0.12% (±0.3 ºC) at 0 ºC, Class B |
Circuit Types |
N/A Single, 3-Wire |
Electrical Connection |
N/A 1/2 in. National Pipe Thread (NPT) Conduit with 6 in. Flying Leads |
Standard Finish [Max] |
N/A 32 micro-inches maximum 32 µin |
Pressure Ratings for Tube |
N/A 500 psi34.5 bar |
Resistance Temperature Device (RTD) Element |
N/A PT100 Ω at 32 ºF (0 ºC), α=0.00385 International Electrotechnical Commission (IEC 751) |
Lead Wires |
N/A Stranded 22 AWG standard, Polyvinyl Chloride (PVC) or Polytetrafluoroethylene (PTFE) Insulation |
Self-Heating |
N/A 50 mW / ºC Typical in Moving Water |
Insulation Resistance |
N/A
Single Element Probes: 100 mega Ω/min. at 500 Vdc, Leads to Case Dual Element Probes: 100 mega Ω/min. at 100 Vdc, Between Element and Leads to Case |
Transition |
N/A Sheath to Wire Transition Maximum Temperature 266 ºF (130 ºC) |
Warranty |
N/A 3 y |
Stem Diameters |
N/A 1/4 in |
Stem Lengths |
N/A 9 in |
Related Items |
N/A
50-090-304-SS, 1/2" National Pipe Thread (NPT) Stepped Shank, 9" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell (Quote) 75-090-304-SS, 3/4" National Pipe Thread (NPT) Stepped Shank, 9" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell ($115.68) 75-090-316-SS, 3/4" National Pipe Thread (NPT) Stepped Shank, 9" Length, 1/2" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell ($129.33) |
Stock |
N/A Yes |
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
Prop 65 Warnings |
N/A
![]() |
Thermowells |
N/A Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument. |