Items |
![]() 254-16-16/40inH2O-1-43-71-TC 25 Series 2" Tri Clamp, Range Adjustable from 0 - 16 inH2O to 0 - 40 inH2O, 0.2% of Adjusted Span, 4 to 20 mA/2-Wire + Hart® Protocol Sanitary Transmitter with PG9 Cable Gland and Transparent Cover |
![]() 254-16-29/145-1-43-71-TC 25 Series 2" Tri Clamp, Range Adjustable from 29 to 145 psig, 0.2% of Adjusted Span, 4 to 20 mA/2-Wire + Hart® Protocol Sanitary Transmitter with PG9 Cable Gland and Transparent Cover |
![]() 254-16-40/160inH2O-1-43-71-TC 25 Series 2" Tri Clamp, Range Adjustable from 0 - 40 inH2O to 0 - 160 inH2O, 0.2% of Adjusted Span, 4 to 20 mA/2-Wire + Hart® Protocol Sanitary Transmitter with PG9 Cable Gland and Transparent Cover |
|||
Description |
N/A
|
|||||
Type | N/A Pressure and Level Transmitter | |||||
Tri-Clamp Size | N/A 2 in | |||||
Weight | N/A 2.2 lb | |||||
Full Scale Best Fit Straight Line (BFSL) Accuracy (±) | N/A 0.2 % of adjusted span % | |||||
Storage Temperature [Min] | N/A -20 ºC-4 ºF | |||||
Storage Temperature [Max] | N/A 100 ºC212 ºF | |||||
Housing Material | N/A 304 Stainless Steel, 316 Stainless Steel | |||||
Output Signal | N/A 4 mA to 20 mA 2-wire, 4 mA to 20 mA 2-wire and Hart® signal | |||||
Electrical Connection | N/A PG9 Cable Gland | |||||
Environmental Rating | N/A Ingress Protection (IP66) (National Electrical Manufacturers Association (NEMA) 4X), Ingress Protection (IP68) (National Electrical Manufacturers Association (NEMA) 6) optional | |||||
Series | N/A 25 | |||||
Connection Material | N/A 316 Stainless Steel | |||||
Pressure Range | N/A 0 to 16 inH2O0 to 40 inH2O | N/A 29 to 145 psig0 to 803 inH2O0 to 4017 inH2O | N/A 1.45 to 5.8 psig0 to 40 inH2O0 to 160 inH2O | |||
Stability | N/A < 0.1%/year | |||||
Adjustment | N/A By 3 push buttons on display or optional Hart® signal | |||||
Response Time | N/A <100 ms | |||||
Service Life | N/A <10 y | |||||
Measuring Element | N/A 316 Stainless Steel (Hastelloy C or Tantalum optional) | |||||
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
|||||
Additional Information |
N/A
|
|||||
Options | N/A Transparent Cover (for Display) (TC) | |||||
Digital Indicators | N/A NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. | |||||
Sanitary Clamps and Gaskets |
N/A
1-1/2" (CR 12) 2" (CR 16) 2-1/2" (CR 20) 3" (CR 24) NBR Gasket 1-1/2" (BG 12) 2" (BG 16) 2-1/2" (BG 20) 3" (BG 24) PTFE Gasket 1-1/2" (TG 12) 2" (TG 16) 2-1/2" (TG 20) 3" (TG 24) |
|||||
Prop 65 Warnings |
N/A
![]() |
|||||
Stock | N/A | N/A | N/A Yes | |||
|