Items |
![]() 623-100-1-1-2-6 0 to 100 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output, 1/4" National Pipe Thread (NPT) Male Pressure Transmitter with 1/2" National Pipe Thread (NPT) Conduit (6 ft Cable Attached) |
![]() 623-15000-1-1-2-6-20 0 to 15,000 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output, 1/4" National Pipe Thread (NPT) Male Pressure Transmitter with 1/2" National Pipe Thread (NPT) Conduit (20 ft Cable Attached) |
![]() 623-2-1-1-2-6 0 to 2 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output, 1/4" National Pipe Thread (NPT) Male Pressure Transmitter with 1/2" National Pipe Thread (NPT) Conduit (6 ft Cable Attached) |
![]() 623-30/30-1-1-8-6 -30 inHg to 30 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output, 1/2" National Pipe Thread (NPT) Male Pressure Transmitter with 1/2" National Pipe Thread (NPT) Conduit (6 ft Cable Attached) |
![]() 623-30-1-1-2-6 0 to 30 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output, 1/4" National Pipe Thread (NPT) Male Pressure Transmitter with 1/2" National Pipe Thread (NPT) Conduit (6 ft Cable Attached) |
|||||
Description |
N/A
|
|||||||||
Type | N/A Pressure Transmitter | |||||||||
Connection Type | N/A Male National Pipe Thread (MNPT) | |||||||||
Weight | N/A 12 oz | |||||||||
Storage Temperature [Min] | N/A -300 ºC-22 ºF | |||||||||
Storage Temperature [Max] | N/A 100 ºC212 ºF | |||||||||
Housing Material | N/A 316 Stainless Steel | |||||||||
Connection Size | N/A 1/4 in | N/A 1/4 in | N/A 1/4 in | N/A 1/2 in | N/A 1/4 in | |||||
Connection Size (Search Only) | N/A 1/4 in | N/A 1/4 in | N/A 1/4 in | N/A 1/2 in | N/A 1/4 in | |||||
Full Scale Best Fit Straight Line (BFSL) Accuracy (±) | N/A 0.25 % | |||||||||
Output Signal | N/A 4 mA to 20 mA, 2-wire | |||||||||
Electrical Connection | N/A 1/2 in. NPT male conduit with 6 ft integral cable | |||||||||
Environmental Rating | N/A Ingress Protection (IP65) to Ingress Protection (IP67) dependent upon electrical connection | |||||||||
Series | N/A Stainless Steel Threaded Connection | |||||||||
Connection Material | N/A 316 Stainless Steel | |||||||||
Pressure Range | N/A 0 to 100 psig | N/A 0 to 15,000 psig | N/A 0 to 2 psig | N/A -30 inHg to 30 psig | N/A 0 to 30 psig | |||||
Absolute Pressure Range | N/A 0 to 100 psia | |||||||||
Stability | N/A ≤ ±0.2% full scale for 1 year, non-accumulating | |||||||||
Response Time | N/A ≤1 ms | |||||||||
Service Life | N/A > 100,000,000 Load Cycles | |||||||||
Compensated Temperature Range | N/A 32 to 176 ºF0 to 80 ºC | |||||||||
Note for Compensated Temperature Range |
N/A
Zero effect is ±0.011% full scale/ºF within compensated range Span effect is ±0.011% full scale/ºF within compensated range |
|||||||||
Media Temperature Range | N/A -40 to 212 ºF-40 to 100 ºC | |||||||||
Ambient Temperature Range | N/A -22 to 176 ºF-30 to 80 ºC | |||||||||
Power Requirement |
N/A
10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire) 6 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire, 0.5 Vdc to 4.5 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire) |
|||||||||
Current for 4 to 20 Milliampere (mA) | N/A 0.020 A | |||||||||
Resistance for 1 to 5 Direct Current (DC) Voltage, 3-Wire | N/A ≥ 10,000 Ω | |||||||||
Measuring Element | N/A 623 Series is 316 stainless steel for ranges up through 0 psi to 300 psi, 316 stainless steel and Elgiloy for ranges 0 psig to 500 psig and higher | |||||||||
Electrical Protection | N/A Reverse polarity, over-voltage and short circuit protected | |||||||||
Electromagnetic Rating | N/A European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection | |||||||||
Shock According to International Electrotechnical Commission (IEC) 60068-2-27 | N/A 1,000 g | |||||||||
Vibration According to International Electrotechnical Commission (IEC) 60068-2-6 | N/A 20 g | |||||||||
Warranty | N/A 3 y | |||||||||
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
|||||||||
Application |
N/A
|
|||||||||
Additional Information |
N/A
NOSHOK 621 and 622 Series transmitters are Factory Mutual and Canadian Standards Association approved for use in hazardous location applications as follows:
|
|||||||||
Options and Accessories |
N/A
|
N/A 20 foot cable/lead attached to 1/2" NPT Male Conduit w/ 6 foot integral cable |
N/A
|
N/A
|
N/A
|
|||||
Assembly Options | N/A NOSHOK offers multiple assembly options to meet your specific system requirements. Consult factory to discuss your customized solution. | |||||||||
Digital Indicators | N/A NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. | |||||||||
Pressure Snubbers - Piston Type |
N/A
|
|||||||||
Pressure Snubbers - Sintered Type |
N/A
|
|||||||||
Steam Syphons |
N/A
|
|||||||||
Swivel Adapters |
N/A
|
|||||||||
Prop 65 Warnings |
N/A
![]() |
|||||||||
|