Type |
N/A Pressure Transmitter |
Clamp Size |
N/A 1-1/2 in |
Weight |
N/A 1.1 lb |
Storage Temperature [Min] |
N/A -40 ºC212 ºF |
Storage Temperature [Max] |
N/A -40 ºC100 ºF |
Housing Material |
N/A 316 Stainless Steel |
Full Scale Best Fit Straight Line (BFSL) Accuracy (±) |
N/A 0.125 %0.25 % |
Output Signal |
N/A 4 mA to 20 mA, 2-Wire, 0 Vdc to 5 Vdc 3-Wire, 1 Vdc to 5 Vdc 3-Wire, 1 Vdc to 6 Vdc 3-Wire, 0 Vdc to 10 Vdc, 3-Wire, 1 Vdc to 11 Vdc 3-Wire |
Electrical Connection |
N/A M12 x 1 (4-Pin) |
Environmental Rating |
N/A Ingress Protection (IP65) |
Series |
N/A 11 |
Connection Material |
N/A 316 Stainless Steel |
Seal Fill Fluid |
N/A FFL77 White Oil |
Transducer |
N/A Series 615 transducer |
Pressure Range |
N/A 0 to 300 psig |
Stability |
N/A ±0.2% full scale for 1 year, non-accumulating |
Adjustment |
N/A ±10% full scale for zero and span |
Response Time |
N/A ≤10 ms |
Service Life |
N/A > 100,000,000 Load Cycles |
Power Requirement |
N/A 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-Wire, 0 Vdc to 5 Vdc, 3-Wire, 1 Vdc to 5 Vdc, 3-Wire, 1 Vdc to 6 Vdc, 3-Wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-Wire, Vdc to 11 Vdc, 3-Wire) |
Current for 4 to 20 Milliampere (mA) |
N/A 0.020 A |
Resistance for 1 to 5 Direct Current (DC) Voltage Output |
N/A ≤ 5,000 Ω |
Resistance for 0 to 10 Direct Current (DC) Voltage Output |
N/A ≤ 10,000 Ω |
Resistance for 0.5 to 4.5 Direct Current (DC) Voltage Output |
N/A ≤ 4,500 Ω |
Measuring Element |
N/A 316 Stainless Steel |
Electrical Protection |
N/A Reverse polarity, over-voltage and short circuit protection |
Electromagnetic Rating |
N/A European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection |
Shock According to International Electrotechnical Commission (IEC) 60068-2-27 |
N/A 1,000 g |
Vibration According to International Electrotechnical Commission (IEC) 60068-2-6 |
N/A 150 g |
Warranty |
N/A 3 y |
Compensated Temperature Range |
N/A 30 to 175 ºF0 to 80 ºC |
Note for Compensated Temperature Range |
N/A Effect ±0.01%/ºF for zero and span |
Media Temperature Range |
N/A -40 to 300 ºF-40 to 150 ºC |
Ambient Temperature Range |
N/A -40 to 176 ºF-40 to 80 ºC |
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
Options and Accessories |
N/A
|
Digital Indicators |
N/A NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. |
Sanitary Clamps and Gaskets |
N/A
1-1/2" (CR 12) 2" (CR 16) 2-1/2" (CR 20) 3" (CR 24) NBR Gasket 1-1/2" (BG 12) 2" (BG 16) 2-1/2" (BG 20) 3" (BG 24) PTFE Gasket 1-1/2" (TG 12) 2" (TG 16) 2-1/2" (TG 20) 3" (TG 24) |
Caution |
N/A
NOSHOK pressure transmitters or transducers are not to be used in heat sterilization systems as stated in 3A Standard 74-03 paragraph D10.1.2. Diaphragm seal must be installed facing downward or in a vertical position for drainability. Do not install diaphragm seal facing in an upward position. |
Prop 65 Warnings |
N/A
![]() |