Items |
![]() 110-12-4-615-1-13-1-14 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), -30 inHg to 100 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A Connection with ISO 4400 1/2 in. National Pipe Thread (NPT) Conduit |
![]() 110-12-4-615-1-34-1-25 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 5 psig, 4 to 20 mA Output Sanitary Transducer with M12 x 1 (4-Pin) |
![]() 110-12-4-615-1-34-1-36 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 5 psig, 4 to 20 mA Output Sanitary Transducer with 36" Integral Cable |
![]() 110-12-4-615-1-40-1-8 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 15 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A |
![]() 110-12-4-615-1-46-1-1 1-1/2" Sanitary Clamp, ±0.25% Accuracy (Best Fit Straight Line (BFSL), 0 to 60 psig, 4 to 20 mA Output Sanitary Transducer with DIN EN 175301-803 Form A (36" Cable Attached) |
|||||
Description |
N/A
|
|||||||||
Type | N/A Pressure Transmitter | |||||||||
Clamp Size | N/A 1-1/2 in | |||||||||
Weight | N/A 1.1 lb | |||||||||
Storage Temperature [Min] | N/A -40 ºC212 ºF | |||||||||
Storage Temperature [Max] | N/A -40 ºC100 ºF | |||||||||
Housing Material | N/A 316 Stainless Steel | |||||||||
Full Scale Best Fit Straight Line (BFSL) Accuracy (±) | N/A 0.125 %0.25 % | |||||||||
Output Signal | N/A 4 mA to 20 mA, 2-Wire, 0 Vdc to 5 Vdc 3-Wire, 1 Vdc to 5 Vdc 3-Wire, 1 Vdc to 6 Vdc 3-Wire, 0 Vdc to 10 Vdc, 3-Wire, 1 Vdc to 11 Vdc 3-Wire | |||||||||
Electrical Connection | N/A DIN EN 175301-803 Form A Connection with International Organization for Standardization (ISO) 4400 1/2 in. National Pipe Thread (NPT) Conduit | N/A M12 x 1 (4-Pin) | N/A Integral 36 in. Cable | N/A DIN EN 175301-803 Form A (DIN European Standard (EN) 175301-803 Form A) | N/A 36 in. Cable attached to DIN EN 175301-803 Form A | |||||
Environmental Rating | N/A Ingress Protection (IP65) | |||||||||
Series | N/A 11 | |||||||||
Connection Material | N/A 316 Stainless Steel | |||||||||
Seal Fill Fluid | N/A FFL77 White Oil | |||||||||
Transducer | N/A Series 615 transducer | |||||||||
Pressure Range | N/A -30 inHg to 100 psig | N/A 0 to 5 psig | N/A 0 to 5 psig | N/A 0 to 15 psig | N/A 0 to 60 psig | |||||
Stability | N/A ±0.2% full scale for 1 year, non-accumulating | |||||||||
Adjustment | N/A ±10% full scale for zero and span | |||||||||
Response Time | N/A ≤10 ms | |||||||||
Service Life | N/A > 100,000,000 Load Cycles | |||||||||
Compensated Temperature Range | N/A 30 to 175 ºF0 to 80 ºC | |||||||||
Note for Compensated Temperature Range | N/A Effect ±0.01%/ºF for zero and span | |||||||||
Media Temperature Range | N/A -40 to 300 ºF-40 to 150 ºC | |||||||||
Ambient Temperature Range | N/A -40 to 176 ºF-40 to 80 ºC | |||||||||
Power Requirement | N/A 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-Wire, 0 Vdc to 5 Vdc, 3-Wire, 1 Vdc to 5 Vdc, 3-Wire, 1 Vdc to 6 Vdc, 3-Wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-Wire, Vdc to 11 Vdc, 3-Wire) | |||||||||
Current for 4 to 20 Milliampere (mA) | N/A 0.020 A | |||||||||
Resistance for 1 to 5 Direct Current (DC) Voltage Output | N/A ≤ 5,000 Ω | |||||||||
Resistance for 0 to 10 Direct Current (DC) Voltage Output | N/A ≤ 10,000 Ω | |||||||||
Resistance for 0.5 to 4.5 Direct Current (DC) Voltage Output | N/A ≤ 4,500 Ω | |||||||||
Measuring Element | N/A 316 Stainless Steel | |||||||||
Electrical Protection | N/A Reverse polarity, over-voltage and short circuit protection | |||||||||
Electromagnetic Rating | N/A European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection | |||||||||
Shock According to International Electrotechnical Commission (IEC) 60068-2-27 | N/A 1,000 g | |||||||||
Vibration According to International Electrotechnical Commission (IEC) 60068-2-6 | N/A 150 g | |||||||||
Warranty | N/A 3 y | |||||||||
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
|||||||||
Options and Accessories |
N/A
|
|||||||||
Application |
N/A
|
|||||||||
Caution |
N/A
NOSHOK pressure transmitters or transducers are not to be used in heat sterilization systems as stated in 3A Standard 74-03 paragraph D10.1.2. Diaphragm seal must be installed facing downward or in a vertical position for drainability. Do not install diaphragm seal facing in an upward position. |
|||||||||
Digital Indicators | N/A NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. | |||||||||
Sanitary Clamps and Gaskets |
N/A
1-1/2" (CR 12) 2" (CR 16) 2-1/2" (CR 20) 3" (CR 24) NBR Gasket 1-1/2" (BG 12) 2" (BG 16) 2-1/2" (BG 20) 3" (BG 24) PTFE Gasket 1-1/2" (TG 12) 2" (TG 16) 2-1/2" (TG 20) 3" (TG 24) |
|||||||||
Prop 65 Warnings |
N/A
![]() |
|||||||||
|