Skip To Content

Catalog

  • For wastewater and chemical feed applications, as well as most applications with a corrosive media
  • Constructed of corrosion-resistant PP glass fiber reinforced upper housing and PP, PVC or PVDF lower housing
  • Protects pressure or vacuum instruments used on ultra-pure or highly corrosive fluid lines such as demineralized water, sulfuric acid, hydrochloric acid, and caustics
  • 100% non-metallic wetted parts assures maximum chemical and temperature compatibility
Unit of Measure

Specifications

Type

N/A Diaphragm Seal

Style

N/A Non-Replaceable Diaphragm Seal

Instrument Connection Size

N/A 1/2 in

Process Connection

N/A National Pipe Thread (NPT)

Upper Housing Material

N/A Polypropylene (PP)

Diaphragm Material

N/A Ethylene Propylene Diene Monomer (EPDM)-Polytetrafluoroethylene (PTFE) Coated on Process Side

Process Connection Size

N/A 1/2 in

Lower Housing Material

N/A Polypropylene (PP)

Seal Type

N/A Threaded with non-replaceable diaphragm

Lower Housing Connection Size

N/A 1/4 in1/2 in

Lower Housing Connection Type

N/A National Pipe Thread (NPT)

Upper Housing Type

N/A Non-Continuous Duty

Diaphragm Size

N/A 1.77 in

Diaphragm Displacement

N/A 8.9 mL

Instrument Connection Type

N/A National Pipe Thread (NPT)

Warranty

N/A 1 y

Stock

N/A Yes

Instruments

Instrument Type

N/A Gauges, Transducers, Switches

Pressure [Min] for Gauges 2-1/2 to 6 in. Size

N/A 0 to 30 psig

Pressure [Max] for Gauges 2-1/2 to 6 in. Size

N/A 0 to 30 psig

Pressure [Max] for Transducers

N/A 0 to 30 psig

Pressure [Max] for Switches

N/A 0 to 30 psig

Prop 65 Warnings

Prop 65 Warnings

N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Application

Application

N/A
  • Wastewater and chemical feed
  • Deionized water systems
  • Reverse osmosis systems
  • Desalinization systems
  • Electroplating

Limitations Which Apply Are

Limitations Which Apply Are

N/A These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. Gauge failures determined to be caused by over-range, incompatibility with environment or product media and abuse will not be considered under this warranty. NOSHOK, Inc. will, at its discretion, repair or replace the working parts of the damaged gauge without cost to the customer.

In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.

Options and Accessories

Cooling Elements

N/A
  • 1/4" NPT x 1/4" NPT Cooling Element (1/4" NPT x 1/4" NPT-CE)
  • 1/2" NPT x 1/2" NPT Cooling Element (1/2" NPT x 1/2" NPT-CE)
  • Works in combination with diaphragm seal to isolate instrument from high media temperatures
  • Recommended for process temperatures above 212 ºF
  • Requires direct mounted system
  • Effective temperature reductions of 200 ºF depending upon ambient conditions
  • High >212 °F process temperature, low < -40 ºF process temperature
  • All Stainless Steel construction

Diaphragm Seal Fill Options

N/A
  • Glycerin (GY) Not recommended for use in vacuum applications.)
  • Silicone (SL)
  • Halocarbon® (HL)
  • Neobee M20 (NB)
  • Mineral Oil (MO)
  • Propylene Glycol (PG)

Distribution Manifolds

N/A NOSHOK's Distribution Manifolds connect multiple instruments to one diaphragm seal, eliminating multiple connections that lead to possible leak paths.

Plain and Armored Capillaries

N/A
  • 5 ft. SS Armored Flexible Capillary, 1/4" NPT (AC-02-02-5) per ft. adder (AC-02-02-#)
  • 5 ft. SS Armored Flexible Capillary, 1/2" NPT (AC-04-04-5) per ft. adder (AC-04-04-#)
  • Stainless Steel capillaries available with or without Stainless Steel armor
  • Protects the instrument from high or low process temperatures
  • Allows remote mounting of pressure instrument(s)
  • Select the shortest capillary length possible, as changes in ambient temperature conditions may significantly affect the accuracy and response time of the instrument
  • Standard length 5', others available
  • Installation on analog gauges requires a gauge support and gauge adaptor, or other surface mounting provisions
  • Any level difference between the instrument and the seal will result in a pressure indication error; make sure to compensate for the level difference during calibration of the diaphragm seal assembly if the level difference is known
  • Filling options for capillaries
    • Silicone - specify to 10 or 20 feet (SL-C)
    • Halocarbon® - specify to 10 or 20 feet (HL-C)

Seal & Pressure Transmitter/Switch Assembly For Wastewater, Chemical Feed

N/A The NOSHOK All Non-Metallic Diaphragm Seal & Pressure Transmitter/Switch assembly is ideal for water, wastewater & chemical feed applications.

Back to Top