Print Back
  • Easy programming and range adjustment without test pressure via on-board display
  • 10:1 turn down
  • Active temperature compensation
  • 360º rotatable display
  • Hart® protocol output available
Sanitary Level Transmitters
Unit of Measure
1 

Part Number

Description

Storage Temperature [Min]

Storage Temperature [Max]

Electrical Connection

Adjustable Pressure Range

List Price

204-93-47/470inH2O-1-43-28-TC N/A 20 Series Anderson Negele Type SL Long - 6", Range Adjustable from 0 - 47 in H2O to 0 - 470 in H2O, 0.1% of Adjusted Span, 4 to 20 mA/2-Wire + HART® Protocol, 1/2" NPT Female Sanitary Transmitter with Transparent Cover N/A -20 ºC-4 ºF N/A 100 ºC212 ºF N/A 1/2 in. National Pipe Thread (NPT) Female N/A 47 to 470 inH2O1.7 to 17 psig Quote
204-93-47/470inH2O-1-43-71-TC N/A 20 Series Anderson Negele Type SL Long - 6", Range Adjustable from 0 - 47 in H2O to 0 - 470 in H2O, 0.1% of Adjusted Span, 4 to 20 mA/2-Wire + HART® Protocol Sanitary Transmitter with PG9 Cable Gland and Transparent Cover N/A -20 ºC-4 ºF N/A 100 ºC212 ºF N/A PG9 Cable Gland N/A 47 to 470 inH2O1.7 to 17 psig Quote
204-93-6/58-1-43-28-TC N/A 20 Series Anderson Negele Type SL Long - 6", Range Adjustable from 0 - 6 psig to 0 - 58 psig, 0.1% of Adjusted Span, 4 to 20 mA/2-Wire + HART® Protocol, 1/2" National Pipe Thread (NPT) Female Sanitary Transmitter with Transparent Cover N/A -20 ºC-4 ºF N/A 100 ºC212 ºF N/A 1/2 in. National Pipe Thread (NPT) Female N/A 160 to 1,600 inH2O6 to 58 psig Quote
204-93-6/58-1-43-71-TC N/A 20 Series Anderson Negele Type SL Long - 6", Range Adjustable from 0 - 6 psig to 0 - 58 psig, 0.1% of Adjusted Span, 4 to 20 mA/2-Wire + HART® Protocol Sanitary Transmitter with PG9 Cable Gland and Transparent Cover N/A -20 ºC-4 ºF N/A 100 ºC212 ºF N/A PG9 Cable Gland N/A 160 to 1,600 inH2O6 to 58 psig Quote
204-95-47/470inH2O-1-43-28-TC N/A 20 Series King Gage Standard - 6", Range Adjustable from 0 - 47 in H2O to 0 - 470 in H2O, 0.1% of Adjusted Span, 4 to 20 mA/2-Wire + HART® Protocol, 1/2" National Pipe Thread (NPT) Female Sanitary Transmitter with Transparent Cover N/A -20 ºC-4 ºF N/A 100 ºC212 ºF N/A 1/2 in. National Pipe Thread (NPT) Female N/A 47 to 470 inH2O1.7 to 17 psig Quote
204-95-6/58-1-43-28-TC N/A 20 Series King Gage Standard - 6", Range Adjustable from 0 - 6 psig to 0 - 58 psig, 0.1% of Adjusted Span, 4 to 20 mA/2-Wire + HART® Protocol, 1/2" National Pipe Thread (NPT) Female Sanitary Transmitter with Transparent Cover N/A -20 ºC-4 ºF N/A 100 ºC212 ºF N/A 1/2 in. National Pipe Thread (NPT) Female N/A 160 to 1,600 inH2O6 to 58 psig Quote
204-99-6/58-1-43-25-TC N/A 20 Series Tank Mate Medium - 6", Range Adjustable from 0 - 6 psig to 0 - 58 psig, 0.1% of Adjusted Span, 4 to 20 mA/2-Wire + HART® Protocol Sanitary Transmitter with M12 x 1 (4 Pin) and Transparent Cover N/A -20 ºC-4 ºF N/A 100 ºC212 ºF N/A M12 x 1 (4-Pin) N/A 160 to 1,600 inH2O6 to 58 psig Quote
Unit of Measure
1