Intelligent Pressure Transmitter, Min. span 29 psi, max. span 145 psi (lowest vacuum pressure -15 psig), ±0.2% of adjusted span with 4:1 turn down, 4 mA to 20 mA, 2-wire, 3" American National Standards Institute (ANSI) 150# flange, PG9 cable gland
Unit of Measure

Specifications

Product Series

N/A PTI20 Intelligent Pressure Transmitter

Pressure Range

N/A Min. span 29 psi, max. span 145 psi (lowest vacuum pressure -15 psig)
Accuracy1 N/A ±0.2% of adjusted span with 4:1 turn down

Output Signal

N/A 4 mA to 20 mA, 2-wire

Process Connection

N/A 3" American National Standards Institute (ANSI) 150# flange

Electrical Connection

N/A PG9 Cable Gland

Environmental Rating

N/A IP66

Power Requirement

N/A 12 Vdc to 36 Vdc

Materials Of Construction (Wetted Parts)

N/A 316 Stainless Steel with 304 Stainless Steel housing

Media Temperature Range

N/A -4 to 176 ºF-20 to 80 ºC

Applications

N/A
  • Food & beverage
  • Pulp & paper
  • Water & wastewater
  • Power generation
  • General Industrial

Related Items

Related Items

N/A 2070-MFS, 1/2" National Pipe Thread (NPT), Male x Female, 316 Stainless Steel, Hard Seat, 0.187" Orifice Block and Bleed 2-Valve ($320.88)
504-MFS, 1/2" National Pipe Thread (NPT), Male x Female, 316 Stainless Steel, Soft Seat, 0.187" Orifice Needle Valve ($193.25)

Additional Technical Information

Stability

N/A <0.1%/year

Adjustment

N/A By 3 push buttons on display or optional HART® protocol

Response Time

N/A <100 ms

Service Life

N/A >10 y

Ambient Temperature Range

N/A -4 to 158 ºF-20 to 70 ºC

Flange Temperature Range

N/A -4 to 212 ºF-20 to 100 ºC

Connection Material

N/A 316 Stainless Steel

Measuring Element

N/A 316 Stainless Steel (Hastelloy C or Tantalum optional)

Approximate Weight

N/A 3.3 lb

Options and Accessories

Digital Indicators

N/A NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters.

Limitations Which Apply Are

Limitations Which Apply Are

N/A These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.