The HPR-2 Series heated pressure regulator is designed to supply heat to samples entering instrumentation systems. It can be used to preheat liquids, to prevent condensation of gases or to vaporize liquids prior to gas analysis.

The modular design of the HPR-2 consists of heat exchanger and pressure control sections. The pressure control section is patterned after the time proven design of the PR-1 pressure reducing regulator and provides the same excellent outlet pressure stability. The heat exchanger section is made up of a body and heat exchange element. The heat exchange element uses GO Regulator's unique spiral wrapped screen as the heat exchange surface. This screen has up to 100 square inches of heat transfer area and precise design forces all sample flow to pass through the element.more
Unit of Measure

Specifications

Brands

GO Regulator, Inc.

Body Material

316L Stainless Steel

Port Configuration

L - See Diagram for Port Configuration

Temperature Range/Heating Type

75 to 175 ºF

Heater Wattage

200 W

Seat Material

Tefzel®

Flow Coefficient (Cv)

0.06

Outlet Range

0 to 250 psig

Heater Block Type

120 V Alternating Current Voltage (VAC)

Heater Block Porting

Standard Block

Cap Assembly

Tamper-Proof, Standard, Stainless Steel

Options

TCO Thermistor

Options (Not Required)

CMTR

Certifications

Canadian Standards Association (CSA) Certification # LR-82566-5 Certification # TRL03ATEX11001X

Technical Data

Inlet Pressure

Up to 6000 psig at 380 ºF (193 ºC)

Operating Temperature

Up to 500 ºF260 ºC

Typical Applications

Typical Applications

Analytical process sample conditioning systems:
  • Petrochemical refineries
  • Chemical production facilities
  • Pilot plants (chemical & petrochemical)
  • LNG loading and off-loading points
  • Natural gas pipeline sampling

Features and Benefits

Features and Benefits

  • Optional HASTELLOY® C and MONEL®
  • Electropolished body with better than 25 Rafinish in diaphragm cavity for an optimal sealing surface
  • Bubble-tight shutoff
  • Modular pressure control and heat exchanger assemblies for easy maintenance
  • Unique spiral wrapped heat exchange element provides up to 100 square inches of heat transfer area.
  • Optional TCO heating cartridge
  • INCONEL® diaphragm standard

Note

Note

  1. Contact the factory for any additional requirements.
  2. Units that will be used for flammable liquid or gas with fire point at 200ºC or below require the TCO Thermistor. It is also recommended to use the 1-PC body option. In addition, Tefzel and PCTFE seats in these units are recommended to use the captured vent cap option which provides for venting to a safe location.