Skip To Content

Catalog

  • High accuracy 4 mA to 20 mA loop-powered indicators for NOSHOK 11 Series Sanitary, 300, 615/616 Series pressure transmitters and 800 Series temperature transmitters
  • Can be fitted to NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the DIN 175301-803 Form A connector
  • Easily inserted between the transmitter body and the connector
  • Programmable to display a range of -1999 to 9999; may be tilted for better viewing
Unit of Measure

Specifications

Type

Digital Indicator

Series

1800

Process Display

4 digit, 0.4" liquid crystal display (-1999 to 9999)

Operating Temperature [Min]

-20 ºC-4 ºF

Operating Temperature [Max]

50 ºC122 ºF

Input Signals

4 to 20 mA
Accuracy1 <0.2 %

Digit Accuracy (±)

1 %

Storage Temperature

-4 to 153 ºF-20 to 70 ºC

Effect

≤ 0.1% of Full Scale/18 ºF (10 ºC) %

Full Scale Temperature

18 ºF10 ºC

Environmental Rating

IP65 per EN60529

Input Signals Current

4 to 20 mA

Optional Direct Current (DC) Voltage

0 to 10 V

Key Pad

3 programmable function keys for relay option only, located behind the face plate

Power Requirement

Loop powered by sensors excitation

Power Consumption [Max]

40 mA

Drop Direct Current (DC) Voltage

≤ 2 V

Electrical Connection

DIN 175301-803 Form A

Memory

Electrically Erasable Programmable Read-Only Memory (EEPROM)

Non-Condensing Humidity

<90 %

Update Rate

200 ms

Selectable Filtering

0.2 to 1.5 s

Relay Option

1 Transistor, N-Switching

Linearization

2 Point

Electromagnetic Rating

European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326-1, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection

Weight

3 oz

Warranty

1 y

Options

No Options

Limitations Which Apply Are

Limitations Which Apply Are

These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.

In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.

Application

Application

  • Hydraulic and pneumatic systems
  • Pumps and compressors
  • Test equipment and systems
  • Industrial machinery and machine tools
  • Heating, Ventilation, and Air Conditioning (HVAC)
  • Power generation
  • Water and wastewater
  • Stamping and forming presses

Additional Information

Additional Information

  • User selectable digital filtering improves readability in rapidly varying pressure applications
  • All parameters are stored in non-volatile memory so that reprogramming is not necessary in the event of a power failure
  • Currently used with 300 Series Pressure Transmitter and 800 Series Temperature Transmitter

Options and Accessories

Installed Options and Accessories

Optional Relay - 1 x NPN Switch (1)

Note

Note

Indicate display range or order eg. 0-1,000 for 4 mA to 20 mA.
  • 1 Max. error on complete span. Error at calibration point ≤0.1 ºC